ModelsMonitoring & ControlCommunication ProtocolInput Voltage RangeOutput Voltage RangeOutput QuantityIP Rating
N/ATotal monitoringModbusRTU100-277VAC / 312VAC-418VAC or 100VDC-240VDC / -43VDC- -56VDCNominal: 220/250/380VAC or -48/240VDCUp to 48 outputsIP20
N/ATotal monitoring Unit monitoringModbusRTU100-277VAC / 312VAC-418VAC or 100VDC-240VDC / -43VDC- -56VDCNominal: 220/250/380VAC or -48/240VDCUp to 48 outputsIP20
N/ATotal monitoring Unit controlModbusRTU100-277VAC / 312VAC-418VAC or 100VDC-240VDC / -43VDC- -56VDCNominal: 220/250/380VAC or -48/240VDCUp to 48 outputsIP20
N/ATotal monitoring Unit control Unit monitoringModbusRTU100-277VAC / 312VAC-418VAC or 100VDC-240VDC / -43VDC- -56VDCNominal: 220/250/380VAC or -48/240VDCUp to 48 outputsIP20
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYT400400kVA / 400kVA304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
SYT500500kVA / 500kVA304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
SYT600600kVA / 600kVA304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
SYT10001000kVA / 1000kW304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
SYT15001500kVA / 1500kW304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
SYT20002000kVA / 2000kW304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out

SOETECK High-frequency Online UPS, 100-300kVA, Tower, PF1

The SOETECK SY-T Series Online High-frequency …

ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYT100kVA100kVA / 100kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYT120kVA120kVA / 120kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYT180kVA180kVA / 180kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYT200kVA200kVA / 200kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYT240kVA240kVA / 240kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out
SYT300kVA300kVA / 300kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out