Critical Power

Explore Soeteck critical power solutions.

Reliable power infrastructure for continuous operations.

显示 126-130 个结果(共 147 个结果)

SOETECK High-frequency Online UPS, 10-60kVA, Tower, PF1

The SOETECK SY-T Series Online High-frequency …

ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYT10kVA10kVA / 10kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out; 3 phase in, 1 phase out; 1 phase in, 1 phase out
SYT20kVA20kVA / 20kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out; 3 phase in, 1 phase out; 1 phase in, 1 phase out
SYT30kVA30kVA / 30kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase N PE
SYT40kVA40kVA / 40kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase N PE
SYT60kVA60kVA / 60kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase N PE
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYT6kVA6kVA/6kW110~300VAC (± 3%) at 50% load; 176~300VAC (± 3%) at 100% loadNominal: 208/220/230/240 VAC94% (AC mode) ; 98.5% ( ECO mode) ; 92% ( Battery mode )1 phase in, 1 phase out
SYT10kVA10kVA/10kW110~300VAC (± 3%) at 50% load; 176~300VAC (± 3%) at 100% loadNominal: 208/220/230/240 VAC94% (AC mode) ; 98.5% ( ECO mode) ; 92% ( Battery mode )1 phase in, 1 phase out
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYT1K1000VA / 1000W110~300 VAC(Based on load at 50%); 160~300 VAC (Based on load at 100%)Nominal: 200/208/220/230/240 VAC≧ 92% or ≧ 94% at full charged battery ( AC mode ) ; ≧ 96% at full charged battery ( ECO mode ) ; ≧ 86% or ≧ 91% ( Battery mode )1 phase PE
SYT2K2000VA / 2000W110~300 VAC(Based on load at 50%); 160~300 VAC (Based on load at 100%)Nominal: 200/208/220/230/240 VAC≧ 92% or ≧ 94% at full charged battery ( AC mode ) ; ≧ 96% at full charged battery ( ECO mode ) ; ≧ 86% or ≧ 91% ( Battery mode )1 phase PE
SYT3K3000VA / 3000W110~300 VAC(Based on load at 50%); 160~300 VAC (Based on load at 100%)Nominal: 200/208/220/230/240 VAC≧ 92% or ≧ 94% at full charged battery ( AC mode ) ; ≧ 96% at full charged battery ( ECO mode ) ; ≧ 86% or ≧ 91% ( Battery mode )1 phase PE
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYTWinner Pro 1kVA1000VA / 900W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
SYTWinner Pro 2kVA2000VA / 1800W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
SYTWinner Pro 3kVA3000VA / 2700W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
SYTWinner Pro 6kVA6000VA / 5400W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
SYTWinner Pro 10kVA10000VA / 9000W60-145 VAC or 120-300 VAC (Based on load at 50%) ; 90-145 VAC or 180-300 VAC (Based on load at 100%)Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE

SOETECK High-Frequency Online UPS, 1kVA-10kVA, Tower Mount, PF0.9

The SOETECK SY-T Series Winner Pro UPS, Online…

ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYT1kVA1000VA/900W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
SYT2kVA2000VA/1800W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
SYT3kVA3000VA/2700W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
SYT6kVA6000VA/5400W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
SYT10kVA10000VA/9000W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE