Critical Power
SOETECK High-frequency Online UPS, 1kVA-3kVA, Rack/Tower-mounted, PF1
The SOETECK SY-RT Series, Online High-frequency UPS 1kVA-3kVA offers industry-leading PF1 efficiency and true double conversion technology, ensuring clean, stable power delivery with 0ms transfer time for critical equipment. Designed for both rack and tower-mounted configurations, it features a wide input voltage range (110-300VAC) and fast 4ms inverter-to-bypass switching. With 96% efficiency in ECO mode and adjustable charging current up to 8A, it is an ideal choice for IT systems, server rooms, and sensitive applications requiring reliable power protection.
- UPS Structure
- Online Double Conversion
- Input Voltage
- 100/110/115/120/127VAC, 208/220/230/240VAC
- Output Voltage
- 100/110/115/120/127VAC, 208/220/230/240VAC
- Power Factor
- ≥ 0.99 @ 100% load
Overview
The SOETECK SY-RT Series, Online High-frequency UPS 1kVA-3kVA delivers industry-leading power protection with a PF1 output power factor, maximizing usable power for connected loads. Featuring true double conversion technology, it ensures seamless, clean, and stable power for critical equipment, eliminating risks of power disruptions and fluctuations.
Designed for versatility, the UPS supports both rack and tower-mounted configurations, offering flexibility for IT infrastructure deployments. Its wide input voltage range of 110-300VAC adapts to unstable grid conditions, while advanced ECO mode improves efficiency to over 96%, reducing operational costs.
With an adjustable charging current (up to 8A) and hot-swappable batteries, the SOETECK SY-RT Series provides extended runtime options and simplified maintenance. Fast switching (4ms for Inverter to Bypass) and a comprehensive LCD display ensure continuous monitoring and reliable power protection for servers, networking, and sensitive electronics.
Key Features
True Double Conversion Technology
- Delivers zero transfer time (0ms) from AC Mode to Battery Mode for uninterrupted power supply
- Fast 4ms transfer from Inverter to Bypass ensures smooth operation during overload or fault conditions
- Provides pure sinewave output with low harmonic distortion, protecting sensitive electronics
High Power Factor Efficiency
- Output power factor of 1.0 delivers full-rated power for connected equipment
- Optimized AC Mode efficiency ≥91% for energy savings and lower operational costs
- Advanced ECO Mode achieves efficiency up to 96%, reducing energy consumption
Scalable Backup Power
- Supports up to 6 hot-swappable batteries for extended runtime and simplified maintenance
- Adjustable charging current up to 8A via LCD panel, ensuring faster battery recovery
- Built-in high power charger supports up to 1000W capacity for extended loads
Flexible and Compact Design
- Supports both rack-mounted and tower-mounted installations for versatile deployment
- Compact footprint with depth starting at 410mm for space-constrained environments
Wide Input Voltage Range
- Accepts wide input voltage range: 110-300VAC, adapting to unstable power grids
- Compatible with 50/60Hz frequency converter mode, ideal for global applications
Intelligent Monitoring and Management
- Comprehensive LCD display for real-time status monitoring, including UPS load, battery level, and fault conditions
- Supports RS232, USB communication and optional SNMP for remote monitoring and control
- Equipped with programmable Emergency Power Off (EPO) function for added safety
Applications
- Small to Medium Server Rooms
- Network Equipment
- Data Centers
- Retail POS Systems
- Security and Surveillance
- Medical Equipment
Model Range
The SOETECK SY-RT Series, Online High-frequency UPS 1kVA-3kVA is engineered for critical power protection with PF1 efficiency and true double conversion technology. Featuring zero transfer time for AC to battery mode and a fast 4ms transfer for inverter to bypass, it ensures uninterrupted power delivery. Its flexible rack/tower-mounted design, hot-swappable batteries, and adjustable charging current (up to 8A) make it an ideal choice for IT systems, small data centers, and sensitive electronics.
| Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
|---|---|---|---|---|---|
| SYRT1K | 1000VA / 1000W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | ? 89% or ? 91% ( AC mode ) ; ? 96% ( ECO mode ) ; ? 88% or ? 90% ( Battery mode ) | 1 phase PE |
| SYRT1.5K | 1500VA / 1500W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | ? 89% or ? 91% ( AC mode ) ; ? 96% ( ECO mode ) ; ? 88% or ? 90% ( Battery mode ) | 1 phase PE |
| SYRT2K | 2000VA / 2000W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | ? 89% or ? 91% ( AC mode ) ; ? 96% ( ECO mode ) ; ? 88% or ? 90% ( Battery mode ) | 1 phase PE |
| SYRT3K | 3000VA / 3000W | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | Nominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC | ? 89% or ? 91% ( AC mode ) ; ? 96% ( ECO mode ) ; ? 88% or ? 90% ( Battery mode ) | 1 phase PE |
Technical Specifications
| Capacity | 1000VA/1000W ; 1500VA/1500W ; 2000VA/2000W ; 3000VA/3000W |
|---|---|
| Nominal Voltage | 100/110/115/120/127 VAC or 200/208/220/230/240 VAC |
| Voltage Range | 55-150 VAC ± 5% or 110-300 VAC ± 5% @ 50% load 80-150 VAC ± 5% or 160-300 VAC ± 5% @ 100% load |
| Frequency Range | 40Hz ~ 70 Hz |
| Power Factor | ≧ 0.99 @ nominal voltage (100% load) |
| Harmonic Distortion(THDi) | ≦ 5% @ nominal input voltage |
| Output Voltage | 100*/110*/115*/120/127 VAC or 200*/208*/220/230/240 VAC |
| AC Voltage Regulation (Batt. Mode) | ± 1% |
| Frequency Range (Synchronized range) | 57 ~ 63 Hz or 47 ~ 53 Hz |
| Frequency Range (Battery mode) | 60Hz ± 0.1Hz or 50 Hz ± 0.1Hz |
| Current Crest Ratio | 3:1 (max.) |
| Harmonic Distortion | ≦2 % THD (Linear Load) ; ≦ 4 % THD (Non-linear Load) |
| Transfer Time AC Mode to Batt. Mode | Zero |
| Transfer Time Inverter to Bypass | 4 ms (Typical) |
| Waveform (battery mode) | Pure Sinewave |
| AC Mode | ≧89% @ full charged battery / ≧91% @ full charged battery |
| ECO Mode | ≧96% @ full charged battery |
| Battery Mode | ≧88% / ≧90% |
| Battery type | 12 V / 9 Ah ; 12 V / 7 Ah |
| Numbers | 2/3/3/4/6/6 |
| Typical recharge time | 3 hours recover to 95% capacity for internal battery@ 2A charging current |
| Charging Current | 100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable 200/208/220/230/240 VAC models: default 2A, max. 12A adjustable ; Default: 2A, Max: 8A adjustable |
| Charging Voltage | 27.4 VDC ± 1% / 41.1 VDC ± 1% / 41.1 VDC ± 1% / 54.8 VDC ±1% / 82.1 VDC ±1% / 82.1 VDC ±1% |
| LCD | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
| Battery mode | Sounding every 5 seconds |
| Low battery | Sounding every 2 second |
| Overload | Sounding every second |
| Fault | Continuously sounding |
| Dimension, D x W x H(mm) | 410 x 438 x 88 / 410 x 438 x 88 / 510 x 438 x 88 / 630 x 438 x 88 / 630 x 438 x 88 |
| Net Weight (without battery) (kgs) | 6.6/7.8/8.1/9.4/10.6/12.4 |
| Net Weight (w/built-int battery) (kgs) | 11.6/14.1/15.5/19.5/23.3/27.5 |
| Humidity | 20-90 % RH @ 0- 40°C (non-condensing) |
| Noise level | Less than 50dB @ 1 Meter |
| Altitude | 10% de-rating for over 1000m (The altitude should not exceed 3000m) |
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
| EMC/safety | (EMC 1-1.5K: EN62040-2 C1, 2K-3K EN62040-2 C2) for CE models |
Resources
Find supports from SOETECK teams
If you are interested in this product, please share your industry background and specific requirements, along with your expected services. These will help us provide you with more personalized solutions and accurate quotes.