Critical Power
SOETECK High-frequency Online UPS, 10-60kVA, Tower, PF1
The SOETECK SY-T Series Online High-frequency UPS, 10-60kVA, Tower, PF1 offers robust and efficient power protection for mission-critical systems. With true double-conversion technology, a power factor of 1.0, and three-phase input/output support, it ensures clean and reliable power delivery. Its wide input voltage range of 110-300V and high efficiency of 95.5% in ECO mode make it an energy-efficient choice for industrial setups, IT networks, and data centers. Optional monitoring via SNMP, USB, or RS-232 enhances system control and reliability.
- UPS Structure
- Online Double Conversion
- Input Voltage
- 3x360/380/400/415VAC
- Output Voltage
- 3 x 360/380/400/415VAC
- Power factor
- ≥ 0.99 @ 100% load
Overview
The SOETECK SY-T Series Online High-frequency UPS, 10-60kVA, Tower, PF1 is a high-performance power protection solution designed for mission-critical applications. This series offers a robust and efficient power backup system with true double-conversion technology, ensuring clean and stable power for sensitive equipment. Supporting three-phase input and three-phase output, it delivers exceptional reliability for industrial systems, IT networks, and data centers.
With capacities ranging from 10kVA to 60kVA, the UPS features a wide input voltage range of 110-300V (at 50% load), making it compatible with unstable power grids and generator inputs. The system achieves a power factor of 1.0, providing full-rated power for connected devices and optimizing energy utilization. Its high efficiency of up to 95.5% in ECO mode minimizes energy loss, significantly reducing operational costs and environmental impact.
The SOETECK SY-T Series UPS also incorporates intelligent battery management, ensuring efficient charging and extending battery lifespan. Optional remote monitoring through SNMP, USB, and RS-232 interfaces provides real-time system visibility, while its modular design allows for seamless scalability to meet growing power demands. This UPS is an ideal solution for businesses seeking reliable and energy-efficient power protection for critical operations.
Key Features
Exceptional Power Protection
- True double-conversion technology ensures clean and stable power delivery, safeguarding sensitive equipment from power disturbances.
- The power factor of 1.0 provides full-rated power, maximizing system performance and energy utilization.
- Supports three-phase input and output (3-in/3-out), ensuring compatibility with industrial-grade systems.
High Energy Efficiency
- Achieves up to 95.5% efficiency in ECO mode, significantly reducing energy loss and operating costs.
- A wide input voltage range of 110-300V (at 50% load) ensures reliable operation in unstable grids and generator-supported environments.
- Low harmonic distortion (<4% THD at 100% load) enhances the stability and performance of connected equipment.
Advanced Battery Management
- Intelligent charging system extends battery lifespan and optimizes backup power availability.
- Modular battery configurations support flexible runtime adjustments to meet diverse application requirements.
- Charging current up to 8-36A ensures rapid battery recovery during critical operations.
Comprehensive Monitoring and Control
- Optional remote monitoring via SNMP, USB, and RS-232 enables real-time system management and control.
- Intuitive LCD interface provides detailed insights into load status, input/output voltage, battery health, and operating conditions.
- Audible alarms and fault indicators ensure timely responses to critical system events.
Reliable and Scalable Design
- Robust tower design supports seamless integration into industrial and IT environments.
- Scalable architecture allows for future expansion to meet growing power demands.
- Complies with global safety standards, ensuring reliability and durability in challenging operating conditions.
Applications
- Industrial Automation Systems
- Data Centers and IT Networks
- Healthcare Equipment
- Telecommunication Systems
- Banking and Financial Systems
- Critical Manufacturing Processes
Model Range
The SOETECK SY-T Series Online High-frequency UPS, 10-60kVA, Tower, PF1 offers versatile models to meet various operational requirements. The 10kVA and 20kVA models are ideal for small to medium-sized setups, providing reliable power and compact design. For larger-scale applications, the 30kVA, 40kVA, 50kVA, and 60kVA models deliver higher capacities, extended runtimes, and enhanced performance. With a wide input voltage range of 110-300V, three-phase input/output, and high efficiency of up to 95.5%, these models ensure seamless power protection for demanding environments. Optional remote monitoring through SNMP, USB, and RS-232 enhances control and operational efficiency.
| Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
|---|---|---|---|---|---|
| SYT10kVA | 10kVA / 10kW | 110-300 VAC at 50% load; 176-276 VAC at 100% load | 3 x 360/380/400/415 VAC (3PH N) | 95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode ) | 3 phase in, 3 phase out; 3 phase in, 1 phase out; 1 phase in, 1 phase out |
| SYT20kVA | 20kVA / 20kW | 110-300 VAC at 50% load; 176-276 VAC at 100% load | 3 x 360/380/400/415 VAC (3PH N) | 95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode ) | 3 phase in, 3 phase out; 3 phase in, 1 phase out; 1 phase in, 1 phase out |
| SYT30kVA | 30kVA / 30kW | 110-300 VAC at 50% load; 176-276 VAC at 100% load | 3 x 360/380/400/415 VAC (3PH N) | 95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode ) | 3 phase N PE |
| SYT40kVA | 40kVA / 40kW | 110-300 VAC at 50% load; 176-276 VAC at 100% load | 3 x 360/380/400/415 VAC (3PH N) | 95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode ) | 3 phase N PE |
| SYT60kVA | 60kVA / 60kW | 110-300 VAC at 50% load; 176-276 VAC at 100% load | 3 x 360/380/400/415 VAC (3PH N) | 95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode ) | 3 phase N PE |
Technical Specifications
| Capacity | 10kVA/10kW ; 20kVA/20kW ; 30kVA/30kW ; 40kVA/40kW ; 60kVA/60kW |
|---|---|
| Rated Voltage | 3 phase in 3 phase out /4 phase in 1 phase out/ single phase in single phase out, (optional) ; Three-phase four-wire |
| Rated Voltage | 3x360/380/400/415 VAC (3 phase N PE) |
| Voltage Range | 110-300 VAC @50% load; 176-276 VAC @100% load |
| Frequency Range | 40 ~ 70 Hz |
| Power Factor | ≥ 0.99@100 %Load |
| Harmonic Distortion (THDi) | Linear load<4% |
| Output Voltage | 3 x 360/380/400/415 VAC(3PH N) |
| Output accuracy (battery mode) | ± 1% |
| Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz |
| FrequencyRange (Battery mode) | 50/60 Hz ± 0.1% |
| Current Crest Ratio | 3:1 (max.) |
| Harmonic Distortion (THDv) | ≦2 % THD (Linear Load) ; ≦5 % THD (Non-linear Load) |
| Transfer Time | AC Mode to Battery Mode:None / Inverter to Bypass:None |
| Waveform (Battery mode) | Pure Sinewave |
| Overload Capacity | 100-110% 60 minutes, 111-125% 10 minutes, 126% -150% 1 minute, >150@0ms |
| Rated Voltage | 3 x 380/400/415 VAC(3PH N) |
| Voltage Range | -30% ~ 20%(Adjustable) |
| Frequency Range (Synchronized Range) | 46~54 Hz or 56~64 Hz |
| Overload Capacity | >130% 1 minute |
| Mains Power Mode | 95.5% |
| ECO Mode | 98.5% |
| Battery Mode | 94.5% |
| Battery Type | 12 V / 9 Ah ; 12 V / 9 Ah ; 12 V / 7 Ah ; 12 V / 9 Ah |
| Quantity | (10 10) / (16 16) / (16 16)*2 / (16 16)*2 |
| Charging Capacity | 9 hours to restore to 90% capacity |
| Charging Current (max.) | 1A / 2A |
| Charging Voltage | ±136.5VDC / ±218VDC |
| Battery type | Depends on the capacity of the external battery |
| Quantity | ±8~±10 (adjustable)/ ±16~±20 (optional) ; ±16~±20(adjustable) |
| Charging Current (max.) | 1A~12A (Optional) / 1A to 18A (adjustable) |
| Charging Voltage | ±13.65V*N (n=8~10) / ±13.65V*N(n=16 ~ 20) |
| D * W * H (mm) | 630 x 250 x 827 / 815 x 300 x 1000 / Not Supported 60 kVA |
| Net weight (kg) | 93/125/207/233/Not Supported 60 kVA |
| D * W * H (mm) | 630 x 250 x 827 / 815 x 300 x 1000 |
| Net weight (kg) | 37/40/55/56/89 |
| LCD Display | UPS status, load capacity, battery capacity, input/output voltage, discharge time and fault indication |
| Operating Humidity | 0-40℃ |
| Altitude | 0 ~ 1500m when fully loaded |
| Noise Level | Less than 60dB@1 m / Less than 63dB@1 m / Less than 75dB@1 m |
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC |
| Optional SNMP | Power management supports SNMP management and network management |
Resources
Find supports from SOETECK teams
If you are interested in this product, please share your industry background and specific requirements, along with your expected services. These will help us provide you with more personalized solutions and accurate quotes.