ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYRT1kVA1000VA / 800WNominal: 100/110/115/120/127VAC or 200/208/220/230/240VACNominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
SYRT2kVA2000VA / 1600WNominal: 100/110/115/120/127VAC or 200/208/220/230/240VACNominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
SYRT3kVA3000VA / 2400WNominal: 100/110/115/120/127VAC or 200/208/220/230/240VACNominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
SYRT6kVA6000VA / 4800WNominal: 100/110/115/120/127VAC or 200/208/220/230/240VACNominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
SYRT10kVA10000VA / 8000WNominal: 100/110/115/120/127VAC or 200/208/220/230/240VACNominal: 100/110/115/120/127VAC or 200/208/220/230/240VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYM150/25C150kva304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )95.5% ( Normal mode ) ; 95% ( Battery mode )3 phase N PE
SYM200/25C200kVA304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )95.5% ( Normal mode ) ; 95% ( Battery mode )3 phase N PE
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYM020/10X20kVA(10x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode )3 phase N PE
SYM030/10X30kVA(10x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode )3 phase N PE
SYM040/10X40kVA(10x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode )3 phase N PE
SYM060/10X60kVA(10x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode )3 phase N PE
SYM030/15X30kVA(15x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode )3 phase N PE
SYM045/15X45kVA(15x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode )3 phase N PE
SYM090/15X90kVA(15x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )≥ 95% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 94.5% ( Battery mode )3 phase N PE
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYM3120/05DS5kVA277~478VAC (Line Voltage), 147~277VAC (Line Voltage) at full load, linearly derating from 100% to 50% load220/230/240VAC≥ 94.5% ( Normal mode )3 phase N PE
SYM3120/10DS10kVA277~478VAC (Line Voltage), 147~277VAC (Line Voltage) at full load, linearly derating from 100% to 50% load220/230/240VAC≥ 94.5% ( Normal mode )3 phase N PE
SYM3120/15DS15kVA277~478VAC (Line Voltage), 147~277VAC (Line Voltage) at full load, linearly derating from 100% to 50% load220/230/240VAC≥ 94.5% ( Normal mode )3 phase N PE
SYM3120/20DS20kVA277~478VAC (Line Voltage), 147~277VAC (Line Voltage) at full load, linearly derating from 100% to 50% load220/230/240VAC≥ 94.5% ( Normal mode )3 phase N PE
ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYM020- TX20kVA304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )92% ( Normal mode ) ; 95% ( ECO mode ) ; 92% ( Battery mode )3 phase N PE
SYM040 - TX40kVA304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )92% ( Normal mode ) ; 95% ( ECO mode ) ; 92% ( Battery mode )3 phase N PE
SYM060 - TX60kVA304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )92% ( Normal mode ) ; 95% ( ECO mode ) ; 92% ( Battery mode )3 phase N PE