Critical Power

Explore Soeteck critical power solutions.

Reliable power infrastructure for continuous operations.

显示 141-145 个结果(共 147 个结果)

SOETECK Modular Online UPS 400kVA-1600kVA, 100kVA Power Module

The SOETECK SY-M Series UPS, Online Cabinet Mo…

ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYM400400kVA138~485VAC (138~323VAC linear derating, 324~485VAC no derating)380/400/415VAC ( Line Voltage )≥ 96%3 phase N PE
SYM500500kVA138~485VAC (138~323VAC linear derating, 324~485VAC no derating)380/400/415VAC ( Line Voltage )≥ 96%3 phase N PE
SYM600600kVA138~485VAC (138~323VAC linear derating, 324~485VAC no derating)380/400/415VAC ( Line Voltage )≥ 96%3 phase N PE
SYM800800kVA138~485VAC (138~323VAC linear derating, 324~485VAC no derating)380/400/415VAC ( Line Voltage )≥ 96%3 phase N PE
SYM10001000kVA138~485VAC (138~323VAC linear derating, 324~485VAC no derating)380/400/415VAC ( Line Voltage )≥ 96%3 phase N PE
SYM11001100kVA138~485VAC (138~323VAC linear derating, 324~485VAC no derating)380/400/415VAC ( Line Voltage )≥ 96%3 phase N PE
SYM12001200kVA138~485VAC (138~323VAC linear derating, 324~485VAC no derating)380/400/415VAC ( Line Voltage )≥ 96%3 phase N PE
SYM13001300kVA138~485VAC (138~323VAC linear derating, 324~485VAC no derating)380/400/415VAC ( Line Voltage )≥ 96%3 phase N PE
SYM14001400kVA138~485VAC (138~323VAC linear derating, 324~485VAC no derating)380/400/415VAC ( Line Voltage )≥ 96%3 phase N PE
SYM15001500kVA138~485VAC (138~323VAC linear derating, 324~485VAC no derating)380/400/415VAC ( Line Voltage )≥ 96%3 phase N PE
SYM16001600kVA138~485VAC (138~323VAC linear derating, 324~485VAC no derating)380/400/415VAC ( Line Voltage )≥ 96%3 phase N PE

SOETECK Smart Modular Online UPS 600kVA, 100kVA Power Module

The SOETECK SY-M Series UPS, Smart Online Cabi…

ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYM600/100D600kVA323~478VAC (Line Voltage), full load, at 30~40 ℃; 323~138VAC (Line Voltage), linearly derating load from 100% to 30%, at 30~40 ℃380/400/415VAC ( Line Voltage )96% ( Normal mode ) ; 95% ( Battery mode )3 phase N PE

SOETECK Smart Modular UPS 600kVA , 60kVA Power Module

The SOETECK SY-M Series UPS, Smart Online Cabi…

ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYM600/60D600kVA323~478VAC (Line Voltage), full load, at 30~40 ℃; 323~138VAC (Line Voltage), linearly derating load from 100% to 30%, at 30~40 ℃380/400/415VAC ( Line Voltage )97% ( Normal mode ) ; 96% ( Battery mode )3 phase N PE

SOETECK Modular Online UPS 80kVA-600kVA, 40/50kVA Power Module

The SY-M Modular Online UPS (40-600kVA) is a s…

ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYM080/40X80kVA(40x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )96% ( Normal mode ) ; 96% ( Battery mode )3 phase N PE
SYM100/50X160kVA(40x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )96% ( Normal mode ) ; 96% ( Battery mode )3 phase N PE
SYM160/40X240kVA(40x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )96% ( Normal mode ) ; 96% ( Battery mode )3 phase N PE
SYM200/50X100kVA(50x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )96% ( Normal mode ) ; 96% ( Battery mode )3 phase N PE
SYM240/40X200kVA(50x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )96% ( Normal mode ) ; 96% ( Battery mode )3 phase N PE
SYM300/50X300kVA(50x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )96% ( Normal mode ) ; 96% ( Battery mode )3 phase N PE
SYM400/50X400kVA(50x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )96% ( Normal mode ) ; 96% ( Battery mode )3 phase N PE
SYM500/50X500kVA(50x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )96% ( Normal mode ) ; 96% ( Battery mode )3 phase N PE
SYM600/50X600kVA(50x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )96% ( Normal mode ) ; 96% ( Battery mode )3 phase N PE

SOETECK Modular Online UPS 150kVA-300kVA, 25/30kVA Power Module

The SY-M Modular Online UPS (25-300kVA) is a s…

ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
SYM150/25X150kVA(25x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )95% ( Normal mode ) ; 95% ( Battery mode )3 phase in, 3 phase out
SYM250/25X250kVA(25x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )95% ( Normal mode ) ; 95% ( Battery mode )3 phase in, 3 phase out
SYM120/30X120kVA(30x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )95% ( Normal mode ) ; 95% ( Battery mode )3 phase in, 3 phase out
SYM180/30X180kVA(30x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )95% ( Normal mode ) ; 95% ( Battery mode )3 phase in, 3 phase out
SYM300/30X300kVA(30x)304~485VAC ( Line Voltage ) fully loaded; 304~138AVC ( Line Voltage) linear derating of load from 100% to 40%380/400/415VAC ( Line Voltage )95% ( Normal mode ) ; 95% ( Battery mode )3 phase in, 3 phase out