Critical Power
SOETECK High-frequency Online UPS, 400kVA-2000kVA, Tower, PF1, True Double Conversion
The SOETECK SY-T Series UPS, Online High-frequency UPS, 400kVA-2000kVA, Tower, PF1, True Double Conversion offers unparalleled power protection for mission-critical systems. With a three-phase input/output design, 98.5% efficiency in ECO mode, and flexible battery configurations, it guarantees operational reliability. Advanced DSP controls, modular architecture, and remote management capabilities make it a top choice for data centers, telecommunications, and healthcare facilities.
- UPS Structure
- Online Double Conversion
- Input Voltage
- 380/400/415VAC (line voltage) 220/230/240VAC (phase voltage)
- Output Voltage
- 380/400/415VAC (line voltage); 220/230/2 40V AC (phase voltage)
- Power factor
- ≥ 0.99 @ 100% load
Overview
The SOETECK SY-T Series UPS, Online High-frequency UPS, 400kVA-2000kVA, Tower, PF1, True Double Conversion is designed to deliver premium power protection for large-scale critical applications. With capacities ranging from 400kVA to 2000kVA, this UPS series ensures clean, stable, and uninterrupted power supply, making it an ideal solution for data centers, industrial automation, and healthcare facilities.
Supporting a three-phase input and output (3P/3P) configuration, the UPS features a power factor of 1.0 and achieves efficiency levels up to 97% in normal mode and 98.5% in ECO mode. Its wide input voltage range of 304V to 478V ensures compatibility with unstable power grids, while low harmonic distortion (<3% THD) minimizes interference with sensitive equipment.
Equipped with advanced DSP control technology, the SOETECK SY-T Series offers real-time monitoring and flexible battery management. Additional features such as modular design, a 10-inch LCD touchscreen, and remote connectivity via SNMP, USB, and RS232 ensure ease of operation and scalability to meet the evolving needs of large-scale infrastructures.
Key Features
Reliable Power Protection
- True double-conversion technology delivers clean and stable power for sensitive equipment.
- Power factor of 1.0 maximizes energy utilization for connected systems.
- Low harmonic distortion (<3% THD) ensures smooth performance for non-linear loads.
High Energy Efficiency
- Achieves up to 98.5% efficiency in ECO mode, reducing energy costs and carbon footprint.
- Wide input voltage range of 304V to 478V ensures compatibility with unstable grids and generators.
- Modular design enhances system flexibility, reducing downtime during maintenance.
Advanced Battery Management
- Flexible battery configurations support up to ±240V, optimizing backup runtime.
- Intelligent charging technology with adjustable currents up to 36A ensures rapid recovery.
- Battery efficiency of >97% guarantees reliable power during outages.
Comprehensive Monitoring and Control
- 10-inch LCD touchscreen provides real-time system status and diagnostics.
- Remote management via SNMP, USB, and RS232 ensures operational visibility.
- Integrated bypass switches enable seamless system maintenance without power interruptions.
Robust Design and Safety
- Complies with global safety standards, including IEC 62040-1 and IEC 60950-1.
- IP20 protection and advanced cooling design enhance system reliability.
- Handles overload conditions up to 150% for 1 minute, ensuring uninterrupted operation during surges.
Applications
- Large Data Centers
- Industrial Automation
- Healthcare Facilities
- Banking and Financial Institutions
- Telecommunications Networks
- Energy and Utility Systems
Model Range
The SOETECK SY-T Series UPS, Online High-frequency UPS, 400kVA-2000kVA, Tower, PF1, True Double Conversion includes models ranging from 400kVA to 2000kVA. Each model supports three-phase input and output with low harmonic distortion (<3% THD) and high energy efficiency of up to 98.5% in ECO mode. The modular design allows for easy maintenance and scalability, while advanced DSP controls and flexible battery configurations ensure seamless integration into critical infrastructure. These models are perfect for large-scale applications, offering robust performance, reliability, and energy savings.
| Models | Power Rating | Input Voltage Range | Output Voltage Range | Efficiency | Wiring |
|---|---|---|---|---|---|
| SYT400 | 400kVA / 400kVA | 304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75% | 380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage ) | ? 97% ( Normal mode ); ? 98% ( ECO model ) ; ? 97% ( Battery mode ) | 3 phase in, 3 phase out |
| SYT500 | 500kVA / 500kVA | 304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75% | 380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage ) | ? 97% ( Normal mode ); ? 98% ( ECO model ) ; ? 97% ( Battery mode ) | 3 phase in, 3 phase out |
| SYT600 | 600kVA / 600kVA | 304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75% | 380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage ) | ? 97% ( Normal mode ); ? 98% ( ECO model ) ; ? 97% ( Battery mode ) | 3 phase in, 3 phase out |
| SYT1000 | 1000kVA / 1000kW | 304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75% | 380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage ) | ? 97% ( Normal mode ); ? 98% ( ECO model ) ; ? 97% ( Battery mode ) | 3 phase in, 3 phase out |
| SYT1500 | 1500kVA / 1500kW | 304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75% | 380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage ) | ? 97% ( Normal mode ); ? 98% ( ECO model ) ; ? 97% ( Battery mode ) | 3 phase in, 3 phase out |
| SYT2000 | 2000kVA / 2000kW | 304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75% | 380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage ) | ? 97% ( Normal mode ); ? 98% ( ECO model ) ; ? 97% ( Battery mode ) | 3 phase in, 3 phase out |
Technical Specifications
| Capacity | 400kVA/400kVA ; 500kVA/500kVA ; 600kVA/600kVA ; 1000kVA/1000kW; 1500kVA/1500kW; 2000kVA/2000kW |
|---|---|
| Input mode | 3P N PE |
| Input voltage | 380/400/415VAC(Line voltage) ; "380/400/415VAC (Line voltage) 220/230/240VAC (Phase voltage)" |
| Power factor | >0.99 |
| Main input Current distortion rate | THDi<3% (100% linear load) |
| Voltage range | 304~478VAC (line voltage) full load; 304~228VAC (line voltage) load derated linearly from 100% to 75% |
| Frequency range | 40-70Hz |
| Rated output voltage | 380/400/415VAC(Line voltage); 220/230/240VAC (Phase voltage) |
| Rated frequency | 50/60Hz |
| Power factor | 1 |
| Voltage accuracy | ±1.0% |
| Frequency tracking range | 50/60Hz±3Hz, (can be set to ±0.5~5Hz) ; Adjustable, ±0.5Hz-±5Hz, default ±3Hz |
| Output frequency accuracy | 0.1% |
| Three-phase phase accuracy | 120°±0.5° |
| Frequency tracking rate | 0.1Hz/s to 5Hz/s, (adjustable, default 2Hz/s) ; Adjustable, 0.5Hz/S-3Hz/S, default 0.5Hz/S |
| Peak ratio | 3:1 |
| Inverter overload capability | 110%, switch to bypass after 1 hour; 125%, switch to bypass after 10 minutes; 150%, switch to bypass after 1 minute; >150%, switch to bypass after 200ms |
| Dynamic voltage transient | <5% (20%~80%~20% step load) |
| Dynamic recovery time | <20ms (0%~100%~0% step load) |
| Rated voltage | 380/400/415VAC(Line voltage); 220/230/240VAC (Phase voltage) |
| Bypass voltage range | Can be set, the default is -20%~ 15%; Upper limit: 10%, 15%, 20%, 25%; Lower limits: -10%,-15%,-20%,-30%,-40%. |
| Battery voltage | ±240VDC (32-44 sections can be set) |
| Battery charging power | 20%*active power |
| Charging voltage accuracy | ±1% |
| Main mode | ≥97% |
| Battery mode | ≥97% |
| Display | LCD LED 10-inch color touch screen |
| Safety | IEC62040-1,IEC60950-1 |
| EMS | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4(EFT); IEC61000-4-5(Surge) |
| System protection level | IP20 |
| Noise (1 meter) | 72dB@100% load, 69dB@45% load |
| Operating temperature | 0-40℃ |
| Relative humidity | 0-95% (no condensation) |
| Standard | USB, RS232, RS485, dry contact card, battery cold start, dust screen |
| Option | SNMP card, AS400 card, parallel component, lightning protection component, LBS |
| W*D*H mm | 1200*1000*2000 / 1200*1100*2000 / 2000*1100*2000 / 2800*1100*2000 / 3400*1100*2000 |